Products
Product Introduction

HR4138 SEMI SECS

Product Number:HR4138
HR4138 is a TIRIS Proximity Tag CID/Data Read/Write Controller that supports reading and writing of both single-page and multi-page TIRIS tags. It provides RS-232C and RS-485 communication interfaces and supports the SEMI/SECS Protocol. Operating at 134.2 kHz FSK, the HR4138 can be used with the HR4137 Gate Controller and is suitable for integration into automation systems requiring RFID identification and data read/write capabilities.

 

  • Power Supply: DC 10~24V (±10%), average 60mA and peak 160mA at 12VDC

  • Frequency: 134.2 kHz FSK, supports TIRIS single-page and multi-page tags

  • Environment: Operating temperature -10 ~ +70°C, operating humidity 10 ~ 85% RH

  • Communication: RS-232C / RS-485, supports 4800 / 9600 / 19200 / 28800 bps (default 9600 bps), SEMI/SECS Protocol

  • Construction: Weight 450g MAX., dimensions 147×110×32 mm, secured with two M4 screws

  • Applications: Industrial automation, asset tracking, logistics management

 

General Specifications

Characteristic Specification Comment
Supply Voltage Range DC 10 ~ 24V (+/-10%) Supplied from the power terminals
Current consumption @12VDC Average 60mA ; Peak 160mA Approx. 1A max, with rush current
Transmitting Radio Frequency Typical 134.2KHz FSK
Transponder Type TIRIS Tag Single & Multi page Transponder
Operating ambient temperature -10 ~ +70°C No freezing
Operating ambient humidity 10 ~ 85% RH No dew condensation
Storage ambient temperature -20 ~ +85°C No freezing
Storage ambient humidity 5 ~ 95% RH No dew condensation
Communication interface RS-232C or RS-485 9600 bps (Default), N.8.1 (fixed)
Weight 450g MAX. No freezing
Dimensions 147 × 110 × 32 mm Except for protrusions on connectors
Mounting system Secured with two M4 screws. Use the enclosed washers.

 

Communication Interface Specification

Characteristic Specification
Connector specification RJ45 connector plug
Communication standard RS-232C or RS-485 only for used HR4137 Gate Controller
Synchronization Asynchronous mode, start-stop synchronization
Communications control standard SEMI/SECS protocol for HR4138 CID Read/Write controller
Baud rate 4800, 9600, 19200, 28800 bps (Default 9600)
Character format (fixed) Start bit: 1 / Data bit: 8 / Parity bit: None / Stop bit: 1 / Total: 10
Error control FCS (Frame Check Sequence)
Total cable length RS-232C: 15 m Max.
RS-485: From HR4137 to last one HR4137 Total 1000 m Max.

Related Products

HR4143

HR4143

HR4143 Industrial RFID Reader Controller for TIRIS Proximity Tag

HR4142

HR4142

HR4142 Industrial RFID Reader Gateway / Controller for TIRIS Proximity Tag

HR4138H HSMS/ TCP/IP

HR4138H HSMS/ TCP/IP

HR4138H Industrial RFID Reader Controller for TIRIS Proximity Tag

HR4137

HR4137

HR4137 Industrial RFID Gateway for TIRIS Proximity Tag

HR4132A PLC/ASCII

HR4132A PLC/ASCII

HR4132A Industrial RFID Reader Controller

HR4132S PLC/ASCII

HR4132S PLC/ASCII

HR4132S Industrial RFID Reader Controller for TIRIS Proximity Tag

HR4138S SEMI SECS

HR4138S SEMI SECS

HR4138S Industrial RFID Reader Controller for TIRIS Proximity Tag

Language Selection